# Elevator status for 343 W Old Town Ct

> Live status is not available for 343 W Old Town Ct. Outage counts come from compliance inspection records, not a real-time feed.
> 
> 9 inspection records in the last 365 days.

Canonical: <https://www.elevatoruptime.com/building/1e8e3cad-7f41-4d24-82ac-1ab6c2213a89>
Location: Chicago, US

## Status right now

9 open inspection records on file.

## Reliability

- **Inspection records in last 365 days:** 9

Uptime and time-to-fix are not published for this building because the only data source is compliance inspection records, not a live feed.

## Open inspection records

- **Elevator** — filed May 29, 2026 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #2: CHANGE ROPE GRIPPER PADS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed May 29, 2026 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: BOTH: PROVIDE ADDITIONAL PERMANANET CARTOP LIGHT. 10 FOOT CANLES MUST BE MEASURED FROM ANY AREA OF CARTOP CANOPY. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed May 29, 2026 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE AMBIENT TEMPERATURE CONTROLL IN MACHINE ROOM TO MEET ELEVATOR MANUFACTURES SPECIFICATIONS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed May 29, 2026 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: BOTH: PROVIDE MAXIMUM TOE GUARD LENGTH. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed May 29, 2026 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: CAULK HOISTWAY PIPES AND GREENFIELD WHIPS AT EACH LANDING | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed May 29, 2026 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: BOTH: PROVIDE CAB LIGHT DISCONNECT GROUND OR BOND | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Mar 16, 2026 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: TEST ALL SMOKES, FAID'S & LOBBY PANEL, WHEN READY. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Nov 2, 2012 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PERFORM CATEGORY 5 TEST ON ALL PASSENGER ELEVATOR'S | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Nov 2, 2012 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: SAFE AND EASY ACCESS TO ELEVATOR MACHINE ROOM (MOVE STEP BACK AGAINST WALL BY MACHINE ROOM DOOR) | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr

## Recent history (last 90 days)

No inspection records in the last 90 days.

## Service contractor

Service provider not yet verified. If you maintain these elevators or know who does, submit a tip at <https://www.elevatoruptime.com/building/1e8e3cad-7f41-4d24-82ac-1ab6c2213a89#contractor>

## Data sources

- **Chicago DOB inspections** — 11 records

## Common questions

### Is the 343 W Old Town Ct elevator working right now?

Live status is not published for 343 W Old Town Ct because the only data source is compliance inspection records. 9 open inspection records on file.

### How do I report a broken elevator at 343 W Old Town Ct?

Use the report form at https://www.elevatoruptime.com/report. It takes about 15 seconds and no account is required.

## Report or correct

- **Report a broken elevator or escalator:** <https://www.elevatoruptime.com/report>
- **Building owner or manager? Claim this listing:** <https://www.elevatoruptime.com/building/1e8e3cad-7f41-4d24-82ac-1ab6c2213a89#claim> — or email <mailto:info@elevatoruptime.com?subject=Claim%20building%3A%20343%20W%20Old%20Town%20Ct%20(1e8e3cad-7f41-4d24-82ac-1ab6c2213a89)>
- **Elevator service contractor? Claim your devices:** <https://www.elevatoruptime.com/building/1e8e3cad-7f41-4d24-82ac-1ab6c2213a89#claim-devices> — or send a tip by email <mailto:info@elevatoruptime.com?subject=Contractor%20tip%3A%20343%20W%20Old%20Town%20Ct%20(1e8e3cad-7f41-4d24-82ac-1ab6c2213a89)>

---