# Elevator status for 100 E Huron St

> Not working — 6 active outages at 100 E Huron St.
> 
> 30-day uptime 0.0% · 6 incidents in the last 365 days.

Canonical: <https://www.elevatoruptime.com/building/2f340dd7-1c84-4b7c-b421-0a1bdbb0e371>
Location: Chicago, US

## Status right now

Out since 18d ago.

## Reliability

- **30-day uptime:** 0.0%
- **90-day uptime:** 0.0%
- **Incidents in last 365 days:** 6

## Active outages

- **Elevator out** — earliest started 18d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #4A: REMOVE OR SOFFIT PURPLE METAL BOX @ 49 THAT WAS INSTALLED AND PROTRUDING INTO THE ELEVATOR HOISTWAY WITHOUT THE CITY'S APPROVAL. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 18d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #4A: PROVIDE ELEVATOR ID ON 1ST FLOOR AND ALL MALL SIDE JAMBS. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 18d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: REMOVE HEAT DETECTORS FROM MACHINE ROOM | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 18d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #4A: MOVE ALL CABLE RETAINING CLIPS TO CORRECT SPACING | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 18d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #4A: PROVIDE ELEVATOR EMERGENCY PHONE ILLUMINATION | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 18d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ALL ELEVATORS: PROVIDE FIRE TABS ON ALL HOISTWAY DOORS AT EACH LANDING | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr

## Recent history (last 90 days)

- 2026-08-31 → ongoing · Elevator
- 2026-08-31 → ongoing · Elevator
- 2026-08-31 → ongoing · Elevator
- 2026-08-31 → ongoing · Elevator
- 2026-08-31 → ongoing · Elevator
- 2026-08-31 → ongoing · Elevator

## Service contractor

Service provider not yet verified. If you maintain these elevators or know who does, submit a tip at <https://www.elevatoruptime.com/building/2f340dd7-1c84-4b7c-b421-0a1bdbb0e371#contractor>

## Data sources

- **Chicago Dob Inspection** — 6 records

## Common questions

### Is the 100 E Huron St elevator working right now?

No — 6 active outages at 100 E Huron St. The earliest active outage started 18d ago.

### How do I report a broken elevator at 100 E Huron St?

Use the report form at https://www.elevatoruptime.com/report. It takes about 15 seconds and no account is required.

### What's the 30-day elevator uptime at 100 E Huron St?

The 30-day elevator uptime at 100 E Huron St is 0.0%. That's low — this building has had significant elevator downtime in the last 30 days.

## Report or correct

- **Report a broken elevator or escalator:** <https://www.elevatoruptime.com/report>
- **Building owner or manager? Claim this listing:** <https://www.elevatoruptime.com/building/2f340dd7-1c84-4b7c-b421-0a1bdbb0e371#claim> — or email <mailto:info@elevatoruptime.com?subject=Claim%20building%3A%20100%20E%20Huron%20St%20(2f340dd7-1c84-4b7c-b421-0a1bdbb0e371)>
- **Elevator service contractor? Correct attribution:** <https://www.elevatoruptime.com/building/2f340dd7-1c84-4b7c-b421-0a1bdbb0e371#contractor> — or email <mailto:info@elevatoruptime.com?subject=Contractor%20tip%3A%20100%20E%20Huron%20St%20(2f340dd7-1c84-4b7c-b421-0a1bdbb0e371)>

---
Site overview for agents: <https://www.elevatoruptime.com/llms.txt>