# Elevator status for 65 E Wacker Pl

> Live status is not available for 65 E Wacker Pl. Outage counts come from compliance inspection records, not a real-time feed.
> 
> 22 inspection records in the last 365 days.

Canonical: <https://www.elevatoruptime.com/building/5de8de24-787a-41ad-a300-5f125e88fce3>
Location: Chicago, US

## Status right now

22 open inspection records on file.

## Reliability

- **Inspection records in last 365 days:** 22

Uptime and time-to-fix are not published for this building because the only data source is compliance inspection records, not a live feed.

## Active outages

- **Elevator out** — earliest started 1mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: DO A COMPLETE FIRE RECALL TEST | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 1mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: REMOVE TRAVELING BUFFERS ON CARS AND INSTALL PROPER CWT BUFFERS ( CAN NOT CONTINUOUSLY COMPRESS ) | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 1mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: REQUIRED OIL BUFFER 2.22.4.1(2.4.2) (2.4.2.1)RUNBY NO LESS THEN 6" (2.4.1.5)(2.5.1.2) | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 1mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: INSTALL HAND RAILS ON MACHINE DECK | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 1mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: INSTALL WORKING AC UNIT IN MACHINE ROOM & FIRE RATED SELF CLOSING SELF LOCKIN MACHINE ROOM  DOORS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 1mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: FIRE RATED HOISTWAY AND MACHINE ROOM 2HR FIRE RATED & CANT ALL LEDGES | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 1mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: INSTALL BRAILLE AND CAR IDENTIFICATION ON ALL DOORS FLOORS & EQUIPMENT | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 1mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: DO COMPLETE SAFETY TEST AND ALL EMPTY&125% | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 2mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: BUILD WALL WITH LADDER AND DOORS IN SECONDARY DECK | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 2mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: FIRE RATE HOISTWAY MACHINE ROOM AND PITS 2HR FIRE RATED | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 2mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: DO 125% BRAKE TEST CAR #5 | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 2mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: DO COMPLETE FIRE SEVICE TEST AT THE END OF MODERIZATION | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 2mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: PATCH ALL HOLES IN FLOOR IN MACHINE ROOM | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 2mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: PROPERLY INDENTIFY ALL DISCONNECT | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 2mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: INSTALL SIGHT GUARD STRIKE SIDE OF HOISTWAY DOOR TO BIG OF GAP . | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 2mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: FINISH ALL FLOORS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 2mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: INSTALL STRIKE PLATE AND STINGER BOX FOR TRAVELING BUFFER CWT FRAME | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 2mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: INSTALL AC UNIT IN MACHINE ROOM | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 2mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: PROPERLY INSTALL BRAILLE AND CAR IDENTIFICATION  ALL FLOORS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 2mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: INSTALL FIRE RATED MACHINE ROOM DOORS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 2mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: APPLY FOR TOE GUARD VARIANCE BOTH CARS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 2mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: INSTALL LIGHTS AND GFI RECEPTACLES IN PITS ,SECONDARY AND MACHINE ROOM | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr

## Recent history (last 90 days)

- 2026-10-01 → ongoing · Elevator · inspection record
- 2026-10-01 → ongoing · Elevator · inspection record
- 2026-10-01 → ongoing · Elevator · inspection record
- 2026-10-01 → ongoing · Elevator · inspection record
- 2026-10-01 → ongoing · Elevator · inspection record
- 2026-10-01 → ongoing · Elevator · inspection record
- 2026-10-01 → ongoing · Elevator · inspection record
- 2026-10-01 → ongoing · Elevator · inspection record
- 2026-08-24 → ongoing · Elevator · inspection record
- 2026-08-24 → ongoing · Elevator · inspection record
- 2026-08-24 → ongoing · Elevator · inspection record
- 2026-08-24 → ongoing · Elevator · inspection record
- 2026-08-24 → ongoing · Elevator · inspection record
- 2026-08-24 → ongoing · Elevator · inspection record
- 2026-08-24 → ongoing · Elevator · inspection record
- 2026-08-24 → ongoing · Elevator · inspection record
- 2026-08-24 → ongoing · Elevator · inspection record
- 2026-08-24 → ongoing · Elevator · inspection record
- 2026-08-24 → ongoing · Elevator · inspection record
- 2026-08-24 → ongoing · Elevator · inspection record

## Service contractor

Service provider not yet verified. If you maintain these elevators or know who does, submit a tip at <https://www.elevatoruptime.com/building/5de8de24-787a-41ad-a300-5f125e88fce3#contractor>

## Data sources

- **Chicago DOB inspections** — 22 records

## Common questions

### Is the 65 E Wacker Pl elevator working right now?

Live status is not published for 65 E Wacker Pl because the only data source is compliance inspection records. 22 open or recent records are on file.

### How do I report a broken elevator at 65 E Wacker Pl?

Use the report form at https://www.elevatoruptime.com/report. It takes about 15 seconds and no account is required.

## Report or correct

- **Report a broken elevator or escalator:** <https://www.elevatoruptime.com/report>
- **Building owner or manager? Claim this listing:** <https://www.elevatoruptime.com/building/5de8de24-787a-41ad-a300-5f125e88fce3#claim> — or email <mailto:info@elevatoruptime.com?subject=Claim%20building%3A%2065%20E%20Wacker%20Pl%20(5de8de24-787a-41ad-a300-5f125e88fce3)>
- **Elevator service contractor? Claim your devices:** <https://www.elevatoruptime.com/building/5de8de24-787a-41ad-a300-5f125e88fce3#claim-devices> — or send a tip by email <mailto:info@elevatoruptime.com?subject=Contractor%20tip%3A%2065%20E%20Wacker%20Pl%20(5de8de24-787a-41ad-a300-5f125e88fce3)>

---
Site overview for agents: <https://www.elevatoruptime.com/llms.txt>