# Elevator status for 100 E Huron St

> Not working — 5 active outages at 100 E Huron St.
> 
> 30-day uptime 45.0% · 90-day 81.7% · 5 incidents in the last 365 days.

Canonical: <https://www.elevatoruptime.com/building/608c50b7-c937-457d-9b8c-c1b6c4b4af76>
Location: Chicago, US

## Status right now

Out since 16d ago.

## Reliability

- **30-day uptime:** 45.0%
- **90-day uptime:** 81.7%
- **Incidents in last 365 days:** 5

## Active outages

- **Elevator out** — earliest started 16d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ALL ELEVATORS: PROVIDE FED FROM LABELS FOR MAIN AND CAB LIGHT DISCONNECTS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 16d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #4A: PROVIDE RESTRICTOR ANGLES FOR MALL SIDE OF FASCIA AND  AT 9-10, 10-11, AND 49-50 | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 16d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ALL ELEVATORS: PROVIDE ACCEPTANCE FULL-LOAD TEST SHEET AND GOVEERNOR TEST TAG | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 16d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE SELF-LOCKING MACHINE ROOM DOOR WITH GROUP II SECURITY | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 16d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: TEST: FAIDS/FLOWS; EMERGENCY POWER, LOSS OF COMMUNICATION FOR FINAL | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr

## Recent history (last 90 days)

- 2026-08-31 → ongoing · Elevator
- 2026-08-31 → ongoing · Elevator
- 2026-08-31 → ongoing · Elevator
- 2026-08-31 → ongoing · Elevator
- 2026-08-31 → ongoing · Elevator

## Service contractor

Service provider not yet verified. If you maintain these elevators or know who does, submit a tip at <https://www.elevatoruptime.com/building/608c50b7-c937-457d-9b8c-c1b6c4b4af76#contractor>

## Data sources

- **Chicago Dob Inspection** — 6 records

## Common questions

### Is the 100 E Huron St elevator working right now?

No — 5 active outages at 100 E Huron St. The earliest active outage started 16d ago.

### How do I report a broken elevator at 100 E Huron St?

Use the report form at https://www.elevatoruptime.com/report. It takes about 15 seconds and no account is required.

### What's the 30-day elevator uptime at 100 E Huron St?

The 30-day elevator uptime at 100 E Huron St is 45.0%. That's low — this building has had significant elevator downtime in the last 30 days.

## Report or correct

- **Report a broken elevator or escalator:** <https://www.elevatoruptime.com/report>
- **Building owner or manager? Claim this listing:** <https://www.elevatoruptime.com/building/608c50b7-c937-457d-9b8c-c1b6c4b4af76#claim> — or email <mailto:info@elevatoruptime.com?subject=Claim%20building%3A%20100%20E%20Huron%20St%20(608c50b7-c937-457d-9b8c-c1b6c4b4af76)>
- **Elevator service contractor? Correct attribution:** <https://www.elevatoruptime.com/building/608c50b7-c937-457d-9b8c-c1b6c4b4af76#contractor> — or email <mailto:info@elevatoruptime.com?subject=Contractor%20tip%3A%20100%20E%20Huron%20St%20(608c50b7-c937-457d-9b8c-c1b6c4b4af76)>

---
Site overview for agents: <https://www.elevatoruptime.com/llms.txt>