# Elevator status for 171 N Wabash Ave

> Live status is not available for 171 N Wabash Ave. Outage counts come from compliance inspection records, not a real-time feed.

Canonical: <https://www.elevatoruptime.com/building/c014f555-0bcf-4011-8642-1f4c408f06e3>
Location: Chicago, US

## Status right now

8 open inspection records on file.

## Reliability

- **Inspection records in last 365 days:** 0

Uptime and time-to-fix are not published for this building because the only data source is compliance inspection records, not a live feed.

## Active outages

- **Elevator out** — earliest started 15y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1360: NONCOMPLIANT MANLIFT | Inspector: 6. PROVIDE INSTRUCTION SIGNAGE AT EACH LANDING OF MANLIFT. RULE 6.1 ASME A90.1 | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 15y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1360: NONCOMPLIANT MANLIFT | Inspector: 9. KEEP MAINTENANCE LOG AVAILABLE FOR REVIEW FOR MANLIFT NEAR CONTROLLER. 8.2.4 ASME A90.1 | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 15y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1360: NONCOMPLIANT MANLIFT | Inspector: PROVIDE SAFE FOOTING AT EACH ENTRANCE AND EXIST THE MANLIFT. (CURRENTLY CONCRETE FLOORING IS IN NEED OF REPAIR.) RULE 4.3.4 ASME A90.1 | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 15y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1360: NONCOMPLIANT MANLIFT | Inspector: 1. PROVIDE ADEQUATE LIGHITNG AT EACH FLOOR LANDING AT ALL TIMES FOR BELT MANLIFT RULE 4.3.3 ASME A90. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 15y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1360: NONCOMPLIANT MANLIFT | Inspector: 5. DISCONTINUE THE PRACTICE OF DISABLING ALL SAFETY SWITCHES FOR THE MANLIFT. (CURRENTLY NO SAFETY SWITCHES ARE WORKING CREATING A DANGEROUS AND HAZARDOUS CONDITION.) RULE 5.7 | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 15y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1360: NONCOMPLIANT MANLIFT | Inspector: 7. PROVIDE TOP FLOOR WARNING SIGN AND LIGHT FOR MANLIFT. RULE 6.2 ASME A90.1 | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 15y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1360: NONCOMPLIANT MANLIFT | Inspector: 4. PREVENT UNAUTHORIZED ACCESS TO MANLIFT WITH SELF-CLOSING, SPRING-LOCKED DOORS AT EACH LANDING. RULE 4.5.6 ASME A90.1 | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 15y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1360: NONCOMPLIANT MANLIFT | Inspector: 3. REPAIR HOODS ON UNDERSIDE OF FLOOR OPENINGS ON UP SIDE OF THE MANLIFT. (CURRENTLY HOLES RUSTED THROUGH). RULE 4.4 ASME A90.1 | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr

## Recent history (last 90 days)

No inspection records in the last 90 days.

## Service contractor

Service provider not yet verified. If you maintain these elevators or know who does, submit a tip at <https://www.elevatoruptime.com/building/c014f555-0bcf-4011-8642-1f4c408f06e3#contractor>

## Data sources

- **Chicago DOB inspections** — 8 records

## Common questions

### Is the 171 N Wabash Ave elevator working right now?

Live status is not published for 171 N Wabash Ave because the only data source is compliance inspection records. 0 open or recent records are on file.

### How do I report a broken elevator at 171 N Wabash Ave?

Use the report form at https://www.elevatoruptime.com/report. It takes about 15 seconds and no account is required.

## Report or correct

- **Report a broken elevator or escalator:** <https://www.elevatoruptime.com/report>
- **Building owner or manager? Claim this listing:** <https://www.elevatoruptime.com/building/c014f555-0bcf-4011-8642-1f4c408f06e3#claim> — or email <mailto:info@elevatoruptime.com?subject=Claim%20building%3A%20171%20N%20Wabash%20Ave%20(c014f555-0bcf-4011-8642-1f4c408f06e3)>
- **Elevator service contractor? Claim your devices:** <https://www.elevatoruptime.com/building/c014f555-0bcf-4011-8642-1f4c408f06e3#claim-devices> — or send a tip by email <mailto:info@elevatoruptime.com?subject=Contractor%20tip%3A%20171%20N%20Wabash%20Ave%20(c014f555-0bcf-4011-8642-1f4c408f06e3)>

---
Site overview for agents: <https://www.elevatoruptime.com/llms.txt>