# Elevator status for 35 W Wacker Dr

> Live status is not available for 35 W Wacker Dr. Outage counts come from compliance inspection records, not a real-time feed.

Canonical: <https://www.elevatoruptime.com/building/c4482c68-bbf1-4495-ae9c-0ba5e296f353>
Location: Chicago, US

## Status right now

15 open inspection records on file.

## Reliability

- **Inspection records in last 365 days:** 0

Uptime and time-to-fix are not published for this building because the only data source is compliance inspection records, not a live feed.

## Active outages

- **Elevator out** — earliest started 4y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: UPON COMPLETION OF MODERNIZATION SCHEDULE ALL FIRE SERVICE RECALL & EMERGENCY POWER TESTING | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 5y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #B3 BARRICADE FOR INSIDE EMERGENCY DOORS ( HOISTWAY ) | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 5y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: IDENTIFY POWER SOURCE ON DISCONNECTS FOR ELEVATOR #26 WINSTON | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 5y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: PATCH/CAULK HOISTWAY WITH ATTENTION TO TOP OF HOISTWAY LARGE VOID, BETWEEN FLOORS, BEHIND HALL STATIONS, DUCT, CONDUIT, AND PIPE CHASES FOR ELEVATOR #26 WINSTON | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 5y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: PROVIDE A FIRE EXTINGUSHER MOUNTED IN THE MACHINE ROOM FOR ELEVATOR #26 WINSTON | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 5y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: REPAIR ELEVATOR CAB FAN FOR ELEVATOR #26 WINSTON | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 5y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: PROVIDE ADDITIONAL LIGHTING, GFCI OUTLET IN PIT OF ELEVATOR #23 | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 5y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: PROVIDE STENCIL/INDENTIFY ALL ELEVATOR MACHINE ROOM EQUIPMENT, CROSSHEAD, AND PIT FOR #23 ELEVATOR | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 5y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE ADIQUITE LIGHTING IN THE HIGH RISE MACHINE ROOM. REVIEW ROOM MANY DARK AREAS (GOVERNORS) | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 6y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: GOVERNOR SAFETY TEST FAILED, GOVERNOR TEST NEED TO BE SUCESSFULLY PERFORMED WHILE WITNESSED | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 7y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE ADDITIONAL LIGHTING AND PROVIDE MECHANICAL PROTECTION OF BULBS IN LOW RISE MACHINE ROOM. CURRENTLY INADEQUATE AND UNPROTECTED | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 20y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV0117: REP/REPL DEF ALARM BELL PASS | Inspector: PROVIDE PHONE 2 WAY COMMUNICATION FOR ELEVATORS, RESTAURANT, BUSTLE, GARAGE 23, AND SHUTTLE ON 47TH FLOOR.  EV010199 | inspection_status=CLOSED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 20y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV0228: REP/REPL DEF DRIVE MACH FRT | Inspector: REPLACE LINERS ON DRIVE SHEAVE ELEVATOR #8 | inspection_status=CLOSED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 20y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV0067: TEST G & S ALL ELE | Inspector: 1 YEAR GOVERNOR & SAFETY TEST AND TAG GOVERNOR RULE 1002.2B | inspection_status=CLOSED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 20y ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV0281: PROV FIRE KEY BOX & KEYS PASS | Inspector: PROVIDE FIRE SERVICE KEY BOXES W/LOCK-TYPE FOR CHICAGO FIRE DEPARTMENT ALARM BOX KEY RULE 211.8B | inspection_status=CLOSED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr

## Recent history (last 90 days)

No inspection records in the last 90 days.

## Service contractor

OTIS ELEVATOR COMPANY

_Most recent elevator permits at this address were filed by this firm, according to Chicago DOB Permits (record 3407473). Observed Apr 22, 2026._

Confidence: inferred from permits.

## Data sources

- **Chicago DOB inspections** — 53 records

## Common questions

### Is the 35 W Wacker Dr elevator working right now?

Live status is not published for 35 W Wacker Dr because the only data source is compliance inspection records. 0 open or recent records are on file.

### How do I report a broken elevator at 35 W Wacker Dr?

Use the report form at https://www.elevatoruptime.com/report. It takes about 15 seconds and no account is required.

### Who maintains the elevators at 35 W Wacker Dr?

Recent elevator permits at 35 W Wacker Dr have been filed by OTIS ELEVATOR COMPANY, according to Chicago DOB Elevator Equipment Permit Applications. Service relationships can change — building owners and contractors can submit corrections.

## Report or correct

- **Report a broken elevator or escalator:** <https://www.elevatoruptime.com/report>
- **Building owner or manager? Claim this listing:** <https://www.elevatoruptime.com/building/c4482c68-bbf1-4495-ae9c-0ba5e296f353#claim> — or email <mailto:info@elevatoruptime.com?subject=Claim%20building%3A%2035%20W%20Wacker%20Dr%20(c4482c68-bbf1-4495-ae9c-0ba5e296f353)>
- **Elevator service contractor? Claim your devices:** <https://www.elevatoruptime.com/building/c4482c68-bbf1-4495-ae9c-0ba5e296f353#claim-devices> — or send a tip by email <mailto:info@elevatoruptime.com?subject=Contractor%20tip%3A%2035%20W%20Wacker%20Dr%20(c4482c68-bbf1-4495-ae9c-0ba5e296f353)>

---