# Elevator status for 120 E Delaware Pl

> Live status is not available for 120 E Delaware Pl. Outage counts come from compliance inspection records, not a real-time feed.

Canonical: <https://www.elevatoruptime.com/building/c63996b2-85fa-410f-953b-0ec570793b4f>
Location: Chicago, US

## Status right now

48 open inspection records on file.

## Reliability

- **Inspection records in last 365 days:** 0

Uptime and time-to-fix are not published for this building because the only data source is compliance inspection records, not a live feed.

## Open inspection records

- **Elevator** — filed Feb 14, 2025 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE KICK PLATES FOR CATWALK AREA SURROUNDING PIT LADDER. #26C | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Jul 23, 2024 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: DISCONTINUE OBSCURING THE TOP ACCESS KEY SWITCH ELEVATOR #31 | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed May 1, 2024 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE COUNTERWEITGHT RUNBY SIGNS IN PIT. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed May 1, 2024 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE COUNTERWEITGHT RUNBY SIGNS IN ALL ELEVATOR PITS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed May 1, 2024 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE PUSH/PULL STOP BUTTON IN ALL PITS FOR FINAL. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed May 1, 2024 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: STENCIL FLOOR NUMBER ON INSIDE OF HOISTWAY DOOR FOR FINAL. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed May 1, 2024 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: LABEL CAR TOP AND PIT EQUIPMENT WITH ELEVATOR NUMBER.AND MACHINES, CONTROLLERS, GOVERNORS, AND DISCONNECTS ALL ELEVATORS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed May 1, 2024 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE COUNTERWEIGHT RUNBY SIGNS IN ALL ELEVATOR PITS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed May 1, 2024 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: LABEL CAR TOP AND PIT EQUIPMENT WITH ELEVATOR NUMBER. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Nov 29, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PATCH HOLES IN ALL HOISTWAY WALLS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Nov 29, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ADD HAND GRIPS TO ALL LADDERS. LADDERS TO EXTEND 48 INCHES ABOVE FLOORS/SILLS. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Nov 29, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ALL ELEVATORS: REPLACE OLD WARN DISCONNECTS. PROVIDE DISCONNECTING MEANS WITHIN SIGHT OF MACHINES AND CONTROLLERS. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE ELEVATOR ID ON JAMB AT EACH HOISTWAY ENTRANCE LANDINGS FRONT AND REAR | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: INSTALL FAIDS; AND SCHEDULE PHASE I, PHASE II, EMERGENCY AND AUTOMATIC RECALL UPON COMPLETION OF MODERNIZATION | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: REMOVE ALL ABANDONED PIPES, EQUIPMENT, AND MATERIALS IN ALL MACHINE ROOMS AND LABEL ALL NON ELEVATOR PIPES IN MACHINE ROOM EVERY 6 FEET OF LENGTH | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE 19 FOOT CANDLES OF LIGHTING OVER EACH MACHINE AND CONTROLLER ALL ELEVATORS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE ACCESS TO HOISTWAY (ESCUSSIONS) AT EACH LANDING FRONT AND REAR | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #24: CAULK ALL HOLES AND PENETRATION IN MACHINE ROOM WALL | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #24: PROVIDE 10 FOOT CANDLES OF PERMANENT CARTOP LIGHTING. MEASURE FROM CANOPY ON CARTOP. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #24: PROVIDE ELEVATOR ID ON JAMB AT EACH LANDING FRONT AND REAR | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #24: PROVIDE ACCESS TO HOISTWAY AT EACH LANDING FRONT AND REAR | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #24: STENCIL LANDING ID ON HOISTWAY DOORS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE ACCESS TO ALL HOISTWAY ENTRANCES (ESCUSSIONS) AT ALL LANDING FRONT AND REAR ALL ELEVATORS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #24: PROVIDE 19 FOOT CANDLES OF LIGHTING OVER EACH MACHINE AND CONTROLLER | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: LABEL HIGH VOLTAGE (1000V) CEMENT BLOCK IN MACHINE ROOM | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #24: INSTALL AND TEST FAIDS; PHASE I/II | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #24: PROVIDE ADA TACTILE LANDING IDENTIFICATION ON BOTH JAMBS AT EACH LANDING | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #24: PROVIDE PERMANANENT LOCKABLE MEANS TO SERVICE MACHINE BRAKE | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #24: PROVIDE EMERGENCY LIGHTING IN MACHINE ROOM | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: STENCIL LANDING ID ON HOISTWAY SIDE OF LANDING DOORS ALL ELEVATORS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PATCH AND CAULK ALL HOLES AND PENETRATION IN MACHINE ROOM WALLS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #24: PROVIDE RUNBY SIGN IN PIT | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #24: PROVIDE SENSORED DRIP PAN WITH DRAIN OVER CONTROLLER/MACHINE/DISCONNECTS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: REMOVE ALL UNUSED PIPES IN MACHINE ROOM AND LABEL ALL NON ELEVATOR PIPES IN MACHINE ROOM EVERY 6 FEET THAT CANNOT BE ENCLOSED/SOFFITTED. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 19, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE ADA TACTILE LANDING IDENTIFICATION ON BOTH JAMBS AT EACH LANDING ALL ELEVATORS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 5, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #29: PROVIDE CODE DATA PLATE WITH CODE YEAR IN AFFECT | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 5, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #29: DEMARK MACHINE SLAB | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 5, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #29: PROVIDE ELEVATOR IDENTIFICATION ON TOE GUARD | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 5, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE SELF-CLOSING MACHINE ROOM AND PIT DOOR | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 5, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #29: CORRECT GOVERNOR TAG FOR CAR SIDE GOVERNOR | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 5, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #29: SOFFIT PIPES IN MACHINE ROOM OR PROVIDE SENSORED DRIP PAN WITH DRAIN AWAY FROM EQUIPMMENT IN MACHINE ROOM | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 5, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #29: PROVIDE FED FROM 110V DISCONNECT LABEL | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 5, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #29: MOVE PIT STOP SWITCH TO 47" ABOVE PIT FLOOR AND PROVIDE WORK PLATFORM STOP SWITCH 18" ABOVE PLATFORM | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Oct 5, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: #29: TAG EMERGENCY PHONE TO GIVE ELEVATOR IDENTIFICATION NUMBER | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Aug 14, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: PROVIDE SMOKE DETECTORS OR FLOW SWITCHES FOR SPRINKLERS. AN PROGRAM AUTOMATIC RECALL | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Aug 14, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: PROVIDE A GRATE ON THE FLOOR DRAIN IN THE MACHINE ROOM | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Aug 14, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: PROVIDE COMMUNICATION FAILURE DEVICE FOR ALL ELEVATORS | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator** — filed Aug 14, 2023 · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: REPLACE CANTS ON HOISTWAY LEDGES THAT WERE REMOVED FOR WATER DAMAGE | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr

## Recent history (last 90 days)

No inspection records in the last 90 days.

## Service contractor

Service provider not yet verified. If you maintain these elevators or know who does, submit a tip at <https://www.elevatoruptime.com/building/c63996b2-85fa-410f-953b-0ec570793b4f#contractor>

## Data sources

- **Chicago DOB inspections** — 109 records

## Common questions

### Is the 120 E Delaware Pl elevator working right now?

Live status is not published for 120 E Delaware Pl because the only data source is compliance inspection records. 48 open inspection records on file.

### How do I report a broken elevator at 120 E Delaware Pl?

Use the report form at https://www.elevatoruptime.com/report. It takes about 15 seconds and no account is required.

## Report or correct

- **Report a broken elevator or escalator:** <https://www.elevatoruptime.com/report>
- **Building owner or manager? Claim this listing:** <https://www.elevatoruptime.com/building/c63996b2-85fa-410f-953b-0ec570793b4f#claim> — or email <mailto:info@elevatoruptime.com?subject=Claim%20building%3A%20120%20E%20Delaware%20Pl%20(c63996b2-85fa-410f-953b-0ec570793b4f)>
- **Elevator service contractor? Claim your devices:** <https://www.elevatoruptime.com/building/c63996b2-85fa-410f-953b-0ec570793b4f#claim-devices> — or send a tip by email <mailto:info@elevatoruptime.com?subject=Contractor%20tip%3A%20120%20E%20Delaware%20Pl%20(c63996b2-85fa-410f-953b-0ec570793b4f)>

---
Site overview for agents: <https://www.elevatoruptime.com/llms.txt>