# Elevator status for 1935 W Pershing Rd

> Not working — 10 active outages at 1935 W Pershing Rd.
> 
> 30-day uptime 0.0% · 10 incidents in the last 365 days.

Canonical: <https://www.elevatoruptime.com/building/d3cc6bf1-7571-489d-984c-2535f24ca066>
Location: Chicago, US

## Status right now

Out since 19d ago.

## Reliability

- **30-day uptime:** 0.0%
- **90-day uptime:** 0.0%
- **Incidents in last 365 days:** 10

## Active outages

- **Elevator out** — earliest started 11d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ALL ELEVATORS: LABEL ALL MACHINE ROOM DOORS WITH ELEVATOR IDENTIFICATION. PROVIDE ELEVATOR MACHINE ROOM SIGNAGE. REMOVED ELEVATOR OR NOT, NEEDS SIGNAGE AND I.D. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 19d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ALL ELEVATORS: PATCH HOLES IN HOISTWAY WALLS, 90 MIN FIRE RATED MATERIAL. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 19d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ALL ELEVATORS: PROVIDE 90 MINUTE FIRE RATED SELF CLOSING MACHINE ROOM DOOR. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 19d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ALL ELEVATORS: PROGRAM EMERGENCY PHONES, 24 HOUR ANSWERING SERVICE. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 19d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ALL ELEVATORS: PROVIDE HOISTWAY DOOR INTERLOCK CIRCUIT TO REMOVDE RED TAG. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 19d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ALL ELEVATORS: PERFROM CAT 1 TESTING | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 19d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ALL ELEVATORS: PERFROM CAT 5 TESTING. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 19d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ALL ELEVATORS: REMOVE HOISTWAY DOOR BYPASS BUTTON IN CAB TO REMOVE RED TAG. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 19d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ALL ELEVATORS: REPAIR/REPLCE HOISTWY DOOR INTERLOCK KEEPERS TO REMOVE RED TAG. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 19d ago · Confirmed · source: Chicago Dob Inspection
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ALL ELEVATORS: PROVIDE CAR DOOR GATE SWITCH CIRCUIT TO REMOVE RED TAG. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr

## Recent history (last 90 days)

- 2026-09-08 → ongoing · Elevator
- 2026-08-31 → ongoing · Elevator
- 2026-08-31 → ongoing · Elevator
- 2026-08-31 → ongoing · Elevator
- 2026-08-31 → ongoing · Elevator
- 2026-08-31 → ongoing · Elevator
- 2026-08-31 → ongoing · Elevator
- 2026-08-31 → ongoing · Elevator
- 2026-08-31 → ongoing · Elevator
- 2026-08-31 → ongoing · Elevator

## Service contractor

Service provider not yet verified. If you maintain these elevators or know who does, submit a tip at <https://www.elevatoruptime.com/building/d3cc6bf1-7571-489d-984c-2535f24ca066#contractor>

## Data sources

- **Chicago Dob Inspection** — 12 records

## Common questions

### Is the 1935 W Pershing Rd elevator working right now?

No — 10 active outages at 1935 W Pershing Rd. The earliest active outage started 19d ago.

### How do I report a broken elevator at 1935 W Pershing Rd?

Use the report form at https://www.elevatoruptime.com/report. It takes about 15 seconds and no account is required.

### What's the 30-day elevator uptime at 1935 W Pershing Rd?

The 30-day elevator uptime at 1935 W Pershing Rd is 0.0%. That's low — this building has had significant elevator downtime in the last 30 days.

## Report or correct

- **Report a broken elevator or escalator:** <https://www.elevatoruptime.com/report>
- **Building owner or manager? Claim this listing:** <https://www.elevatoruptime.com/building/d3cc6bf1-7571-489d-984c-2535f24ca066#claim> — or email <mailto:info@elevatoruptime.com?subject=Claim%20building%3A%201935%20W%20Pershing%20Rd%20(d3cc6bf1-7571-489d-984c-2535f24ca066)>
- **Elevator service contractor? Correct attribution:** <https://www.elevatoruptime.com/building/d3cc6bf1-7571-489d-984c-2535f24ca066#contractor> — or email <mailto:info@elevatoruptime.com?subject=Contractor%20tip%3A%201935%20W%20Pershing%20Rd%20(d3cc6bf1-7571-489d-984c-2535f24ca066)>

---
Site overview for agents: <https://www.elevatoruptime.com/llms.txt>