# Elevator status for 123 W Madison St

> Live status is not available for 123 W Madison St. Outage counts come from compliance inspection records, not a real-time feed.
> 
> 14 inspection records in the last 365 days.

Canonical: <https://www.elevatoruptime.com/building/d51aa3c1-27b6-4bb4-9aef-e2666b72550f>
Location: Chicago, US

## Status right now

14 open inspection records on file.

## Reliability

- **Inspection records in last 365 days:** 14

Uptime and time-to-fix are not published for this building because the only data source is compliance inspection records, not a live feed.

## Active outages

- **Elevator out** — earliest started 2mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE STAMPED APPROVAL BY STRUCTURAL ENGINEER VERIFYING PIT FLOOR INTEGRITY FOR OCCUPIED SPACE BELOW. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 3mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: CAR#2-CAR#3: PROVIDE 90 MINUTE FIRE RATED, SELF CLOSING, SELF LOCKING, LABELED SECONDARY DOOR. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 3mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1111: MAINTAIN OR REPAIR HYDRO ELEVA | Inspector: CAR#1: PROVIDE PIT LADDER. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 3mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: CAR#4: ILLEGALLY DECOMISSIONED TRACTION PASSENGER ELEVATOR, HOISTWAY DOORS OPEN TO PUBLIC ON BASEMENT AND LOWER BASEMENT LEVEL, PULL DECOMISSION PERMIT TO BE INSPECTED. HAZARDOUS. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 3mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: CAR#2: PULL PERMIT FOR NEWLY INSTALLED GOVORNER ROPE. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 3mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: CAR#2-CAR#3: PROVIDE PIT DOOR SWITCH. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 3mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ALL ELEVATORS: PROVIDE HOIST ROPE DATA TAG WITH INSTALL DATES. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 3mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: CAR#2-CAR#3: CLEAN PIT. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 4mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ALL ELEVATORS: OPEN PERMIT #100832801 2017 FIRE SERVICE MANDATE | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 4mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ALL ELEVATORS: PERFROM MONTHLY FIRE SERVICE TESTING, PROVIDE CITY DOCUMENTATION. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 4mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ALL ELEVATORS: PROGRAM EMERGENCY PHONE TO 24 HOUR ANSWERING SERVICE, NOT 911. HAZARDOUS. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 4mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: CAR #2: ADDRESS FLOOR LEVELING ISSUE, TRIP HAZARD. HAZARDOUS. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 4mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: CAR #1: ADDRESS RIDE QUALITY. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr
- **Elevator out** — earliest started 4mo ago · Confirmed · source: Chicago DOB inspections
  > Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ALL ELEVATORS: OPEN PERMIT #100832801 2017 FIRE SERVICE MANDATE | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr

## Recent history (last 90 days)

- 2026-08-27 → ongoing · Elevator · inspection record

## Service contractor

Service provider not yet verified. If you maintain these elevators or know who does, submit a tip at <https://www.elevatoruptime.com/building/d51aa3c1-27b6-4bb4-9aef-e2666b72550f#contractor>

## Data sources

- **Chicago DOB inspections** — 14 records

## Common questions

### Is the 123 W Madison St elevator working right now?

Live status is not published for 123 W Madison St because the only data source is compliance inspection records. 14 open or recent records are on file.

### How do I report a broken elevator at 123 W Madison St?

Use the report form at https://www.elevatoruptime.com/report. It takes about 15 seconds and no account is required.

## Report or correct

- **Report a broken elevator or escalator:** <https://www.elevatoruptime.com/report>
- **Building owner or manager? Claim this listing:** <https://www.elevatoruptime.com/building/d51aa3c1-27b6-4bb4-9aef-e2666b72550f#claim> — or email <mailto:info@elevatoruptime.com?subject=Claim%20building%3A%20123%20W%20Madison%20St%20(d51aa3c1-27b6-4bb4-9aef-e2666b72550f)>
- **Elevator service contractor? Claim your devices:** <https://www.elevatoruptime.com/building/d51aa3c1-27b6-4bb4-9aef-e2666b72550f#claim-devices> — or send a tip by email <mailto:info@elevatoruptime.com?subject=Contractor%20tip%3A%20123%20W%20Madison%20St%20(d51aa3c1-27b6-4bb4-9aef-e2666b72550f)>

---
Site overview for agents: <https://www.elevatoruptime.com/llms.txt>