Open compliance records: inspection findings that haven’t been administratively closed. Not a real-time signal that the equipment is unusable today.
On fileElevator
Started Jul 31, 12:00 AM UTC
Chicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
“Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: CLOSE CARTOP JUNCTION BOX AND ELIMINATE LOOSE WIRING. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr”
On fileElevator
Started Jul 31, 12:00 AM UTC
Chicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
“Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE USE AND FED FROM LOCATIONS ON DISCONNECTS. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr”
On fileElevator
Started Jul 31, 12:00 AM UTC
Chicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
“Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: AUTOMATIC SPRINKLER PROTECTION IS PROVIDED IN CONTROL ROOM. NO MEANS IS AUTOMATICALLY PROVIDED TO DISCONNECT ELEVATOR MAINLINE POWER PRIOR TO ACTIVATION OF WATER DISCHARGE. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr”
On fileElevator
Started Jul 31, 12:00 AM UTC
Chicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
“Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: REPAIR EMERGENCY LIGHT UNIT IN ELEVATOR AND TEST WITH CAB LIGHTING DISCONNECT OFF. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr”
On fileElevator
Started Jul 31, 12:00 AM UTC
Chicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
“Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: REPAIR AND RETEST TOP AND BOTTOM DIRECTIONALS AND FINAL LIMITS. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr”
On fileElevator
Started Jul 31, 12:00 AM UTC
Chicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
“Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE SELF CLOSING AND SELF LOCKING DOORS TO CONTROL SPACE. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr”
On fileElevator
Started Jul 31, 12:00 AM UTC
Chicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
“Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: WIRING SCHEMATICS NEEDED ONSITE. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr”
On fileElevator
Started Jul 31, 12:00 AM UTC
Chicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
“Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE ABC FIRE EXTINGUISHER IN CONTROL ROOM. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr”
On fileElevator
Started Jul 31, 12:00 AM UTC
Chicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
“Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: INSTALL LIGHT IN OVERHEAD PER SCOPE OF WORK SUBMITTED TO CITY. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr”
On fileElevator
Started Jul 31, 12:00 AM UTC
Chicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
“Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PLUG OPEN HOLES IN DISCONNECTS. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr”
On fileElevator
Started Jul 31, 12:00 AM UTC
Chicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
“Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: COMPLETE 2 HR FIRE RATING IN OVERHEAD. CURRENTLY YOU CAN SEE INTO CEILINGS OF ADJACENT ROOMS AND GAS PIPE. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr”
On fileElevator
Started Jul 31, 12:00 AM UTC
Chicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
“Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: ELECTRICAL CONDUCTORS SUPPLING DISCONNECTS ARE INSTALLED EXPOSED/ FREE AIR. PROVIDE PROPER RACEWAY AND FITTINGS PER NEC. | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr”
On fileElevator
Started Aug 28, 12:00 AM UTC
Chicago DOB inspectionsrecorded retroactively Aug 28, 12:00 AM UTC
“Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PATCH AND COMPLETE ELEVATOR HOISTWAY WALLS MAINTAIN 2 HOUR RATING. PATCH/ FIRE CAULK GAPS BEHIND MOTOR AND THROUGH WALL TO CONTROL SPACE. (PREVIOUSLY CITED) | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr”
On fileElevator
Started Aug 28, 12:00 AM UTC
Chicago DOB inspectionsrecorded retroactively Aug 28, 12:00 AM UTC
“Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE SILL GUARDS ON ALL HOISTWAY ENTRANCES (1ST FLOOR STILL PENDING COMPLETION) (PREVIOUSLY CITED) | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr”
On fileElevator
Started Aug 28, 12:00 AM UTC
Chicago DOB inspectionsrecorded retroactively Aug 28, 12:00 AM UTC
“Chicago DOB EV violation EV1110: MAINTAIN OR REPAIR ELECT ELEVA | Inspector: PROVIDE GUARDING AROUND HOISTWAY DOORS I.E. SWEEPS, JAMBS... EXCESSIVE GAPS (PREVIOUSLY CITED) | inspection_status=FAILED violation_status=OPEN | evidence: https://data.cityofchicago.org/Buildings/Building-Violations/22u3-xenr”
Key figures
Uptime
Not enough data
Needs a live feed. This building has inspection records only.
Avg time to fix
Not enough data
Needs a live feed.
Records · 365 d
12
Inspection filings
Tracked since
2023
First record Aug 28, 2023
History
12 compliance records in 365 days
Recent records
Last 90 days
Jul 3112 elevator outages
ShowHide
ElevatorChicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
ElevatorChicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
ElevatorChicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
ElevatorChicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
ElevatorChicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
ElevatorChicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
ElevatorChicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
ElevatorChicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
ElevatorChicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
ElevatorChicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
ElevatorChicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
ElevatorChicago DOB inspectionsrecorded retroactively Jul 31, 12:00 AM UTC
City of Chicago Department of Buildings elevator violation inspections. An open record is an inspection finding that has not been marked complied; it is not a report that the elevator is out of service.
We don't yet have a routine outage feed for Chicago.
Common questions
When was the elevator last inspected at 45 E Division St?